Disable character, Disable character on – Datalogic QuickScan Lite QW2100 User Manual
Page 265
Disable Character
Product Reference Guide
255
Disable Character
Specifies the value of the RS-232 host command used to disable the reader.
ASCII characters or any hex value from 0 to 0xFF can be selected.
To set the value:
1. Determine the desired character or value. A setting of 0xFF indicates the the Disable
Character is not used (not available).
2. Use the
on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming
Mode.
4. Scan the bar code: SELECT DISABLE CHARACTER SETTING.
5. Scan the appropriate two alpha-numeric characters from the keypad in
, that represent the desired character/value in step
above. The second character
will cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See
for some examples of how to set this feature.
Table 12. Disable Character Setting Examples
NOTE
Setting to previously defined characters such as XON, XOFF,
or host commands conflicts with normal operation of these
characters. 8-bit data is not recognized when the option
has been set as 7 Data Bits.
STEP
ACTION
EXAMPLES
1
Desired character/value
‘d’
‘}’
‘D’
Disable Command
Not Used
2
Hex equivalent
0x64
0x7D
0x44
0xFF
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT DISABLE CHARACTER VALUE SETTING
5
Scan Two Characters From
‘6’ and ‘4’
‘7’ and ‘D’
‘4’ and ‘4’
‘F’ AND ‘F’
6