Symbologies

180

QuickScan

TM

Lite QW2100

ENTER/EXIT PROGRAMMING MODE

Codabar — cont.

Codabar Set Length 1

This feature specifies one of the bar code lengths for

Codabar Length Control

. Length 1 is

the minimum label length if in

Variable Length

Mode, or the first fixed length if in

Fixed

Length

Mode. Length includes the bar code’s start, stop, check and data characters. The length

must include at least one data character.

The length can be set from 3 to 50 characters. See

Set Length 1 on page 268

for more

detailed programming instructions.

$CCBL1

Select Codabar Length 1 Setting

Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.

~

CANCEL

DEFAULT

03 = Length 1 is 3 Characters