Scanning Active Time

Product Reference Guide

247

Scanning Active Time

This setting specifies the amount of time that the reader stays in scan ON state once the state is
entered. The range for this setting is from 1 to 255 seconds in 1-second increments.

Follow these instructions to set this feature:

1. Determine the desired setting.

2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20

= 020, etc.

3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming

Mode.

4. Scan the bar code: SELECT SCANNING ACTIVE TIME SETTING.

5. Scan the appropriate three digits from the keypad in

Appendix E, Keypad

, that repre-

sent the duration which was determined in the steps above. You will hear a two-beep indi-
cation after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming

Mode.

This completes the procedure. See

Table 4

for some examples of how to set this feature.

Table 4. Scanning Active Time Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

1 Second

90 Sec. (1.5

min.)

180 Sec. (3 min.)

255 Seconds (4.25

min.)

2

Pad leading zero(es)

001

090

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT SCANNING ACTIVE TIME SETTING

5

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘1’

‘0’, ‘9’ and ‘0’

‘1’, ‘8’ and ‘0’

‘2’, ‘5’ and ‘5’

6