beautypg.com

Global prefix/suffix, Example: setting a prefix, Global prefix/suf – Datalogic QuickScan Lite QW2100 User Manual

Page 270

background image

References

260

QuickScan

TM

Lite QW2100

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/
or as a suffix (in a position following the bar code data) as indicated in

Figure 7

.

Figure 7. Prefix and Suffix Positions

Example: Setting a Prefix

In this example, we’ll set a prefix for all symbologies.

1. Determine which ASCII character(s) are to be added to scanned bar code data. In this

example, we’ll add a dollar sign (‘$’) as a prefix.

2. Scan the ENTER/EXIT bar code.

3. Scan the SET GLOBAL PREFIX bar code.

4. Reference the ASCII Chart on the inside back cover of this manual, to find the hex value

assigned to the desired character. The corresponding hex number for the ‘$’ character is
24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from

Appendix E, Key-

pad

.

5. If less than the expected string of 20 characters are selected, scan the ENTER/EXIT bar

code to terminate the string.

6. Scan the ENTER/EXIT bar code once again to exit Programming Mode.

7. The resulting message string would appear as follows:

Scanned bar code data:12345

Resulting message string output: $12345

This option sets up to 20 characters each from the set of ASCII characters or any hex value from
00 to FF. To configure this feature, scan the ENTER/EXIT bar code to place the unit in Pro-
gramming Mode, then the “Set Global Prefix” or “Set Global Suffix,” bar code followed by the
digits (in hex) from the Alphanumeric characters in

Appendix E, Keypad

representing your

desired character(s). If less than the expected string of 20 characters are selected, scan the
ENTER/EXIT bar code to terminate the string. Reference the section,

Example: Setting a

Prefix on page 260

, for more information. Exit programming mode by scanning the

ENTER/EXIT bar code once again.

Prefix

Suffix

AIM ID

Label ID

Label ID

Bar Code Data

00 - 20 Characters (ASCII)

AND

OR

OR...

NOTE

If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.