Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for a new
label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 sec-
onds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a
trigger pull for each label that is read

Follow these instructions to set this feature:

1. Determine the desired setting in milliseconds.

2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-

ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.

3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming

Mode.

4. Scan the bar code: SELECT LABEL GONE TIMEOUT SETTING.

5. Scan the appropriate three alpha-numeric characters from the keypad in

Appendix E,

Keypad

representing the duration which was determined in the steps above. You will hear

a two-beep indication after the last character.

6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming

Mode.

This completes the procedure. See

Table 2

for some examples of how to set this feature.

Table 2. Timeout Setting Examples

NOTE

If you make a mistake before the last character, scan the CANCEL bar
code to abort and not save the entry string. You can then start again at
the beginning.

STEP

ACTION

EXAMPLES

1

Desired Setting

50ms

150ms

1800ms (1.8

sec.)

2550ms (2.55 sec.)

2

Divide by 10 (and pad with

leading zeroes)

005

015

180

255

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT LABEL GONE TIMEOUT SETTING

5

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘5’

‘0’, ‘1’ and ‘5’

‘1’, ‘8’ and ‘0’

‘‘2’, ‘5’ and ‘5’

6

Scan ENTER/EXIT PROGRAMMING MODE