Trigger:slope:levela, Trigger:slope:levelb – RIGOL DS1000D User Manual
Page 46

Programming Guide for DS1000E, DS1000D Series
2-34
The query returns P_WIN_A, P_WIN_B, P_WIN_AB, N_WIN_A, N_WIN_B or
N_WIN_AB.
Example:
:TRIG:SLOP:WIND PA Setup the type of trigger level as rising edge Level A
:TRIG:SLOP:WIND?
The query returns P_WIN_A.
5. :TRIGger:SLOPe:LEVelA
Command Format:
:TRIGger:SLOPe:LEVelA
:TRIGger:SLOPe:LEVelA?
Function Explanation:
The commands set and query the upper boundary “Level A” of trigger level. The
range of
the unit is V/div.
Returned Format:
The query returns the setting value of level in V.
Example:
:TRIG:SLOP:LEVA 2 Setup the upper boundary of trigger level as 2V.
:TRIG:SLOP:LEVA?
The query returns 2.000e+00.
6. :TRIGger:SLOPe:LEVelB
Command Format:
:TRIGger:SLOPe:LEVelB
:TRIGger:SLOPe:LEVelB?
Function Explanation:
The commands set and query the lower boundary “LEVel B” of trigger level. The
range of
the unit is V/div.
Returned Format: