Item

Description

Read
Priv-password

Specifies the read only user privacy password to be used for privacy (encryption).

Range: 8 to 32 bytes

Default: PrivPassword

Write User Name

Specifies the reading/writing user name.

Range: Up to 32 bytes

Default: restrict

Note:
The same name specified as the Discovery User Name and Write User Name
cannot be used.

Write Security
Level

Specifies the security level for reading/writing user.

Choices: None, Auth-password, Auth-password/Priv-password

Default: Auth-password/Priv-password

Write
Auth-password

Specifies the reading/writing user authentication password to be used for
authentication.

Range: 8 to 32 bytes

Default: (excluding colons)

Write
Priv-password

Specifies the reading/writing user privacy password to be used for privacy
(encryption).

Range: 8 to 32 bytes

Default: (excluding colons)

Encryption
Algorithm

Select an encryption algorithm.

Choices: DES, AES-128

Default: DES

Authentication
Method

Select an authentication method.

Choices: MD5, SHA-1

Default: MD5