Time Adjustment Settings

Item

Description

Time Adjustment

Select whether or not the time is automatically adjusted with NTP.

Choices: Enable, Disable

Default: Disable

NTP Server Address

Specifies the NTP server address.

IPv4 address, IPv6 address or FQDN (Fully Qualified Domain Name) can be
specified.

Range: Up to 63 bytes

Default: 0.0.0.0

Port Number

Specifies the NTP server port number.

Range: 1 - 65535

Default: 123

Time Zone

Specifies the time difference from GMT.

Range: -12:00 - +12:00

Default: 0:00

Adjustment Time

Shows the last modification date and time.

Apply button

Applies the configuration settings for this window.

Clear button

Resets all configuration settings to previous values.

Daylight Saving Time Settings

Item

Description

Daylight Saving Time

Select whether or not daylight saving time is applied.
If Enable is selected, specify how many minutes the time will be adjusted (1 -
150min).

Choices: Enable, Disable

Default: Disable

Configuration Menu Equivalent:
UTILITY

- ADMIN. MANAGEMENT - USER SETTING - DAYLIGHT SAVING

Apply button

Applies the configuration settings for this window.

Clear button

Resets all configuration settings to previous values.