beautypg.com

SMA SB 2000HF-30 Installation User Manual

Page 92

background image

Technical Data

SMA Solar Technology AG

92

SB20HF-30HF-IA-en-32

Installation Manual

Electronic Solar Switch

Torque

Grounding systems

Data storage capacity

Efficiency

Electrical endurance in the event of a short circuit,
with a nominal current of 35 A

Min. 50 switching processes

Maximum switching current

35 A

Maximum switching voltage

800 V

Maximum PV power

12 kW

Degree of protection when plugged

IP65

Degree of protection when unplugged

IP65

Enclosure lid screws

6 Nm

Additional grounding screw

6 Nm

SUNCLIX lock nut

2 Nm

Multi‑function relay connection

0.5 Nm

IT grid

Suitable with ungrounded PV array

TN‑C grid

Suitable

TN‑S grid

Suitable

TN‑C‑S grid

Suitable

TT grid

Suitable

Split Phase

Suitable

Daily energy yield

63 days

Daily yields

30 years

Event messages for users

250 events

Event messages for installers

250 events

Maximum efficiency, η

max

96.3%

European weighted efficiency, η

EU

95.4%

This manual is related to the following products: