Technical Data

SMA Solar Technology AG

90

SB20HF-30HF-IA-en-32

Installation Manual

Protective devices

General Data

DC reverse polarity protection

Short‑circuit diode

Input‑side disconnection device

Electronic Solar Switch

DC overvoltage protection

Thermally monitored varistors

AC short‑circuit current capability

Current control

Grid monitoring

SMA Grid Guard 3

Maximum permissible fuse protection

25 A

Ground fault monitoring

Insulation monitoring: R

iso

> 1 M Ω

Galvanic isolation

Available

Width x height x depth with
Electronic Solar Switch

348 mm x 580 mm x 145 mm

Weight

17 kg

Length x width x height of packaging

600 mm x 400 mm x 450 mm

Transport weight

21 kg

Climatic category according to IEC 60721‑2‑1

4K4H

Operating temperature range

− 25°C … +60°C

Maximum permissible value for relative humidity,
non‑condensing

100%

Maximum operating altitude above mean sea
level

3 000 m

Noise emission (typical)

≤ 38 dB(A)

Power loss in night operation

< 1 W

Topology

HF transformer

Cooling concept

OptiCool: temperature‑controlled fan

Fan connection

Designed for safe disconnection

in accordance with DIN EN 50178:1998‑04

Degree of protection according to IEC 60529

IP65

Protection class (according to IEC 62103)

I