6.4 Connecting the PV Array (DC)

6.4.1 Conditions for the DC Connection

• Requirements for the PV modules of the connected strings:

– Same type
– Same number
– Identical alignment
– Identical tilt

• The connection cable of the PV modules must be equipped with connectors. The DC connectors

for the DC connection are included in the delivery.

• The following limiting values at the DC input of the inverter must not be exceeded:

Use of Y adapters for parallel connection of strings
Y adapters may not be visible within close proximity of the inverter or freely accessible.

• The DC electric circuit must not be interrupted by adaptors.
• Observe the procedure for disconnecting the inverter as described in section

8 "Disconnecting the Inverter from Voltage Sources" (page 58).

Sunny Boy

Maximum input voltage

Maximum input current

SB 2000HF‑30

700 V

12 A

SB 2500HF‑30

700 V

15 A

SB 3000HF‑30

700 V

15 A