Electrical Connection

SMA Solar Technology AG

40

SB20HF-30HF-IA-en-32

Installation Manual

17. Screw the pressure screw (E) tightly onto the threaded sleeve (C). The pressure screw serves to

seal and relieve strain.

☑ The AC connection socket has been screwed together.

18. If the AC connection socket is not immediately connected to the inverter, close the AC jack on

the inverter with the protective cap provided.

19. Make sure that the inverter has been secured with the connection element in order to prevent it

from being lifted out, as per section 4.3 "Mounting the Inverter with the Wall Mounting Bracket"
(page 17).

20. Insert the AC connection socket into the AC jack on

the inverter until it audibly snaps into place.
Remove the protective cap beforehand, if required.

☑ The AC cable is connected to the inverter.

DANGER!
Danger to life due to high voltages in the inverter.

• Do not switch on the miniature circuit‑breaker until the PV array has been connected

and the inverter is securely closed.