6.4.2 Assembling the DC Connectors

All PV module connection cables must be equipped with the included DC connectors before
connecting them to the inverter.
To assemble the DC connectors, proceed as follows. Ensure the connectors have the correct polarity.
The DC connectors have the symbols "+" and " − ".

Cable Requirements

• Use a PV1‑F cable.

Procedure

1. Lead the stripped cable all the way into the

DC connector.

2. Press the clamping bracket down.

☑ The clamping bracket snaps audibly into place.

3. Ensure that the cable is correctly positioned:

Result

Measure

☑ If the stranded wire is visible in the chamber

of the clamping bracket, the cable is
correctly positioned.

• Proceed to step 4.

...

...