4 mounting the quick module, Mounting the quick module – SMA SB 2000HF-30 Installation User Manual
Page 30
The Communication Module (Quick Module)
SMA Solar Technology AG
30
SB20HF-30HF-IA-en-32
Installation Manual
5.4 Mounting the Quick Module
1. Disconnect the inverter from the AC and DC side as described in section 8 "Disconnecting the
Inverter from Voltage Sources" (page 58).
2. Make sure that the inverter has been secured with the connection element in order to prevent it
from being lifted out, as per section 4.3 "Mounting the Inverter with the Wall Mounting Bracket"
(page 17).
3. Put the Quick Module into the designated holes on
the retainer.
4. Push the Quick Module upwards in the guide slot
until it clicks into place.
5. Check that the Quick Module is correctly seated.
The loops of the Quick Module and the retainer
must be positioned flush on top of each other.
☑ The Quick Module is mounted.
NOTICE!
Damage to the Quick Module due to improper installation in the inverter.
The Quick Module can be damaged if incorrectly installed in the inverter.
• Check the Quick Module for visible external damage before installation.
• Carefully install the Quick Module, as described in the following.