SMA Solar Technology AG

The Communication Module (Quick Module)

Installation Manual

SB20HF-30HF-IA-en-32

27

If the inverter is not set to the installation country, there are several ways of configuring the required
country standard.

• Setting via 2 rotary switches in Quick Module, as described in section 5.3.4 "Setting the

Country Standard and Language using the Rotary Switch" (page 28).

• Alternatively you can adjust the setting via the "CntrySet" or "Set country standard" parameters

with a communication product (e.g. Sunny Data Control or Sunny Explorer), once you have
commissioned the inverter.

• If you require adjusted parameter settings for your installation site, you can change these with

the help of a communication product.

5.3.3 Opening the Quick Module

1. If the Quick Module is already connected to the inverter, proceed as follows:

– Disconnect the inverter from the AC and DC side as described in section 8 "Disconnecting

the Inverter from Voltage Sources" (page 58).

– Pull the Quick Module out to the first stopper.

2. Open the lower flap of the Quick Module.

3. Open the lid of the Quick Module until it locks into

place.

☑ The Quick Module is open. You can now set the installation country and the language via the

rotary switches as described in the following section.