beautypg.com

Quick module – SMA SB 2000HF-30 Installation User Manual

Page 31

background image

SMA Solar Technology AG

The Communication Module (Quick Module)

Installation Manual

SB20HF-30HF-IA-en-32

31

5.5 Changes via Rotary Switches after Installation of the

Quick Module

If you have already connected the Quick Module to the inverter and would like for example to
configure the installation country or the display language via the rotary switches, then proceed as
follows:

1. Disconnect the inverter from the AC and DC side as described in section 8 "Disconnecting the

Inverter from Voltage Sources" (page 58).

2. Make sure that the inverter has been secured with the connection element in order to prevent it

from being lifted out, as per section 4.3 "Mounting the Inverter with the Wall Mounting Bracket"
(page 17).

3. Pull the Quick Module out to the first stopper.

4. Flip the flap up and pen the lid until it locks into

place.

5. See section 5.3.4 "Setting the Country Standard and Language using the Rotary Switch"

(page 28) for setting the installation country and the display language.

6. See section 5.3.5 "Communication via Bluetooth" (page 28) for assigning the NetID via

Bluetooth.

7. Close the lid of the Quick Module and flip the flap

down again until it locks into place.