beautypg.com

7 failure categories, 8 warnings and error messages – SMA SI 4548-US User Manual

Page 208

background image

20  Troubleshooting

SMA America, LLC

208

SI4548-6048-US-BE-en-20

Operating Manual

20.7 Failure Categories

The Sunny Island distinguishes between five different levels of errors, each requiring different user
interaction:

20.8 Warnings and Error Messages

The meanings of the warnings and errors displayed by the Sunny Island are described in the following
table:

E853

Sunny Island Charger #3 detected

E854

Sunny Island Charger #4 detected

E901

SOC recalibration started

E902

SOC recalibration stopped

E903

Derating started

E904

Derating stopped

E905

Preventive self-disconnection to protect the battery from deep discharge

Level

Designation

Display

Meaning

1

Warning

Warning

Warning, device continues to run. There is an explicit
information on the Home Screen that a warning was
recorded.

2

Malfunction 1 Malfunction

Failure that can only be detected during operation.
Device switches off. Device can be restarted
immediately (autostart).

3

Malfunction 2 Malfunction

Failure that can also be detected in standby mode.
Device switches off. The device can only be restarted
(autostart) once the system detects that the
malfunction has ended.

4

Error

Failure

Device error, device switches off. User interaction
required (troubleshooting, confirmation, manual
restart)

5

Device defect Defect

Device is defect. Device switches off and does not
switch on again. Permanent operation inhibition.
Device must be replaced.

Display no.

Description

This manual is related to the following products: