5 system settings (250#) – SMA SI 4548-US User Manual
Page 190
19 Parameter Lists
SMA America, LLC
190
SI4548-6048-US-BE-en-20
Operating Manual
19.2.5 System Settings (250#)
No. Name
Description
Value
Explanation
Default value
01
AutoStr
Autostart
If the value 0 has
been set, this
means that the
autostart is
deactivated.
3
02
Dt
Date
MM/DD/YYYY
99.99.9999
03
Tm
Time in hours,
minutes and
seconds
HH:MM:SS
99:99:99
04
BeepEna
Button sound
Off
Disable
On
On
Enable
05
ClstCfg
Cluster
configuration
Slave1
Cluster slave 1
1Phase1
Slave2
Cluster slave 2
Slave3
Cluster slave 3
1Phase1
Single-phase, 1
Sunny Island
1Phase2
Single-phase, 2
Sunny Island
1Phase3
Single-phase,
3 Sunny Island
1Phase4
Single-phase, 4
Sunny Island
2Phase2
Split-phase, 2
Sunny Island
2Phase4
Double split-phase,
4 Sunny Island
3Phase
Three-phase, 3
Sunny Island
MC-Box
Setting for
Multicluster
operation