beautypg.com

2 safety, 1 intended use, Safety – SMA SB 3600SE-10 User Manual

Page 8: Intended use

background image

2 Safety

2.1 Intended Use

The inverter, the Battery Pack, the energy meters and if applicable, the Sunny Home Manager,
make up a system for optimization of self-consumption in a household. The inverter is equipped with
two MPP trackers and converts the direct current from the PV array into grid-compliant alternating
current. The Battery Pack is used for the intermediate storage of the energy.
The product is designed for indoor use only.
The product must only be operated at ambient temperatures from 0°C to +40°C and at a relative
humidity between 5% and 95%.
The product must not be exposed to any direct solar irradiation.
The product must not be installed in areas containing highly flammable materials or gases.
The product must not be mounted in potentially explosive atmospheres.
The inverter must only be operated with a Battery Pack type "BAT-2.0-A-SE-10" (status as of: March
2014). An updated list of batteries approved by SMA Solar Technology AG is available at
www.SMA-Solar.com.
The product must only be operated with PV arrays of protection class II, in accordance with
IEC 61730, application class A. The PV modules must be compatible with this product.
PV modules with a high capacity to ground must only be used if their coupling capacity does not
exceed 1.4 μF (for information on how to calculate the coupling capacity, see the Technical
Information "Leading Leakage Currents" at www.SMA-Solar.com).
The product must only be used in countries for which it is approved or released by SMA Solar
Technology AG and the grid operator.
All components must remain within their permitted operating ranges at all times.
The product is not suitable for setting up a DC distribution grid.
Use this product only in accordance with the information provided in the enclosed documentation
and with the locally applicable standards and directives. Any other application may cause
personal injury or property damage.
Alterations to the product, e.g. changes or modifications, are only permitted with the express written
permission of SMA Solar Technology AG. Making unauthorized changes will void the warranty
and will normally result in invalidation of the operating permit. SMA Solar Technology AG shall not
be held liable for any damages caused by such changes.
Any use of the product other than described in the Intended Use section does not qualify as
intended use.
The enclosed documentation is an integral part of this product. Keep the documentation in a
convenient place for future reference and observe all instructions contained therein.
All type labels must be permanently attached.

2 Safety

SMA Solar Technology AG

Operating Manual

SB36-50SE-BE-en-11

8

This manual is related to the following products: