18. Ensure that no voltage is present on the

AC connecting terminal plate between L and PE
using a suitable measuring device. Insert the test
probe into each round opening of the terminal.

19. If you are using the multifunction relay, ensure that no voltage is present between any of the

terminals on the multifunction relay and PE on the AC connecting terminal plate.

20.

Damage to the inverter due to electrostatic discharge
Touching electronic components can cause damage to or destroy the inverter through
electrostatic discharge.

• Ground yourself before touching any component.

10 Disconnecting the Inverter from Voltage Sources

SMA Solar Technology AG

Operating Manual

SB36-50SE-BE-en-11

56