2 general data – SMA SB 3600SE-10 User Manual
Page 58

SB 3600SE-10
SB 5000SE-10
Total harmonic distortion of the output cur-
rent with total harmonic distortion of the AC
voltage < 2%, and AC power > 50% of the
rated power
≤ 4%
≤ 4%
Maximum output current under fault condi-
tions
34 A
34 A
Rated power frequency
50 Hz
50 Hz
AC power frequency*
50 Hz / 60 Hz
50 Hz / 60 Hz
Operating range at AC power frequency
50 Hz
45 Hz to 55 Hz
45 Hz to 55 Hz
Operating range at AC power frequency
60 Hz
55 Hz to 65 Hz
55 Hz to 65 Hz
Power factor at rated power
1
1
Displacement power factor cos φ, ad-
justable
0.8 underexcited to 1 to
0.8 overexcited
0.8 underexcited to 1 to
0.8 overexcited
Feed-in phases
1
1
Connection phases
1
1
Overvoltage category in accordance with
IEC 60664-1
III
III
* depending on the configured country data set
Efficiency
SB 3600SE-10
SB 5000SE-10
Maximum efficiency, η
max
97.1%
97.1%
European efficiency, η
EU
96.5%
96.7%
11.2 General Data
Width x height x depth of the inverter with Bat-
tery Pack and protective cover
877 mm x 711 mm x 252 mm
Width x height x depth of the inverter
460 mm x 715 mm x 217 mm
Weight of the inverter with Battery Pack and
protective cover
59 kg
Weight of the inverter
30 kg
Length x width x height of the inverter packag-
ing
800 mm x 600 mm x 336 mm
11 Technical Data
SMA Solar Technology AG
Operating Manual
SB36-50SE-BE-en-11
58