beautypg.com

2 general data – SMA SB 3600SE-10 User Manual

Page 58

background image

SB 3600SE-10

SB 5000SE-10

Total harmonic distortion of the output cur-
rent with total harmonic distortion of the AC
voltage < 2%, and AC power > 50% of the
rated power

≤ 4%

≤ 4%

Maximum output current under fault condi-
tions

34 A

34 A

Rated power frequency

50 Hz

50 Hz

AC power frequency*

50 Hz / 60 Hz

50 Hz / 60 Hz

Operating range at AC power frequency
50 Hz

45 Hz to 55 Hz

45 Hz to 55 Hz

Operating range at AC power frequency
60 Hz

55 Hz to 65 Hz

55 Hz to 65 Hz

Power factor at rated power

1

1

Displacement power factor cos φ, ad-
justable

0.8 underexcited to 1 to

0.8 overexcited

0.8 underexcited to 1 to

0.8 overexcited

Feed-in phases

1

1

Connection phases

1

1

Overvoltage category in accordance with
IEC 60664-1

III

III

* depending on the configured country data set

Efficiency

SB 3600SE-10

SB 5000SE-10

Maximum efficiency, η

max

97.1%

97.1%

European efficiency, η

EU

96.5%

96.7%

11.2 General Data

Width x height x depth of the inverter with Bat-
tery Pack and protective cover

877 mm x 711 mm x 252 mm

Width x height x depth of the inverter

460 mm x 715 mm x 217 mm

Weight of the inverter with Battery Pack and
protective cover

59 kg

Weight of the inverter

30 kg

Length x width x height of the inverter packag-
ing

800 mm x 600 mm x 336 mm

11 Technical Data

SMA Solar Technology AG

Operating Manual

SB36-50SE-BE-en-11

58