beautypg.com

SMA SB 3600SE-10 User Manual

Page 59

background image

Length x width x height of the packaging of the
protective cover of the Battery Pack

800 mm x 600 mm x 336 mm

Transport weight of the inverter

38 kg

Transport weight of the protective cover of the
battery

4 kg

Climatic category in accordance with IEC
60721-3-3*

3K5

Environmental category

Interior

Pollution degree outside the inverter

3

Pollution degree inside the inverter

2

Operating temperature range

0°C to +40°C

Maximum permissible value for relative humid-
ity, non-condensing

95%

Maximum operating altitude above mean sea
level (MSL)

2,000 m

Typical noise emission

≤25 dB(A)

Power loss in night mode

<0.5 W

Maximum data volume per inverter with Speed-
wire/Webconnect

550 MB/month

Additional data volume when using the Sunny
Portal live interface

600 kB/hour

Topology

transformerless

Cooling concept

Convection

Degree of protection in accordance with
IEC 60529

IP54

Protection class in accordance with IEC 62103

I

Grid configurations

TN-C, TN-S, TN-C-S, TT (when V

N_PE

< 30 V)

Approvals and national standards
As of June 2014**

AS 3100, AS 4777, C10/11:2012, CE,

CEI 0-21, DIN EN 62109-1 / IEC 62109-1,

DIN EN 62109-2 / IEC 62109-2, EN 50438,

G59/3, G83/2, NEN 50438, PPC, PPDS,

RD 1699, VDE 0126-1-1, VDE AR-N 4105,

VDE-ST-Li-ESS-001:2013/03, VFR 2014

* deviating conditions apply

** EN 50438: does not apply to all national appendices of EN 50438.

IEC 62109-2: This standard requires that either the inverter is connected to Sunny Portal and the fault
alert is activated in Sunny Portal, or that the multifunction relay in the inverter is retrofitted and used as
fault indicator.

11 Technical Data

SMA Solar Technology AG

Operating Manual

59

SB36-50SE-BE-en-11

This manual is related to the following products: