beautypg.com

SMA SB 3600SE-10 User Manual

Page 36

background image

6.

Damage to the inverter due to moisture ingress
The inverter is only properly sealed when all unused DC inputs are closed with DC connectors
and sealing plugs.

• Do not insert the sealing plugs directly into the DC inputs on the inverter.
• For unused DC connectors, push down the

clamping bracket and push the swivel nut
up to the thread.

• Insert the sealing plug into the DC

connector.

• Tighten the DC connector (torque: 2 Nm).

• Insert the DC connectors with sealing plugs into the corresponding DC inputs on the

inverter.

☑ The DC connectors snap audibly into place.

7. Ensure that all DC connectors are securely in place.
8. Flip the DC contact protection down until it

snaps into place. Route the connection cables in
the corresponding bracket.

6 Electrical Connection

SMA Solar Technology AG

Operating Manual

SB36-50SE-BE-en-11

36

This manual is related to the following products: