Settings for the NC editor

Generate backup files

TRUE: Generate backup file after editing NC programs
FALSE: Do not generate backup file after editing NC programs

Behavior of the cursor after deletion of lines

TRUE: Cursor is placed on the preceding line after deletion (iTNC behavior)
FALSE: Cursor is placed on the following line after deletion

Behavior of the cursor on the first or last line

TRUE: Cursor jumps from end to beginning of program
FALSE: Cursor does not jump from end to beginning of program

Line break with multiline blocks

ALL: Always display all lines
ACT: Only display the lines of the active block completely
NO: Only display all lines when block is edited

Activate help

TRUE: Always display help graphics during input
FALSE: Only display help graphics when the CYCLE HELP soft key is set to ON. The CYCLE HELP OFF/ON

soft key is displayed in Programming operating mode after pressing the "Screen layout" key

Behavior of the soft-key row after a cycle entry

TRUE: The cycle soft-key row remains active after a cycle definition
FALSE: The cycle soft-key row is hidden after a cycle definition

Safety check when deleting blocks

TRUE: Display confirmation question when deleting an NC block
FALSE: Do not display confirmation question when deleting an NC block

Line number up to which a test of the NC program is to be run

100 to 9999: Program length for which the geometry is to be checked

DIN/ISO programming: Block number increment

0 to 250: Increments for creation of DIN/ISO blocks in the program

Line number to which identical syntax elements are searched for

500 to 9999: Search for cursored elements with up / down arrow keys

Paths for the end user

List of drives and/or directories

Drives or directories entered here are shown in the TNC’s file manager

FN 16 output path for execution

Path for FN 16 output when no path is defined in the program

FN 16 output path for the Programming and Test Run op. modes

Path for FN 16 output when no path is defined in the program

Settings for the file management

Display of dependent files

MANUAL: Dependent files are displayed
AUTOMATIC: Dependent files are not displayed

Universal Time (Greenwich Mean Time)

Time difference to universal time [h]

–12 to 13: Time difference in hours relative to Greenwich Mean Time

Universal time ()

Time difference to universal time [h]

–12 to 13: Time difference in hours relative to Greenwich Mean Time

serial Interface: See "Setting the data interfaces" on page 346.