5.2 T
ool data
TIME2
Maximum tool life in minutes during TOOL CALL: If the current tool
life reaches or exceeds this value, the TNC changes the tool
during the next TOOL CALL (see also CUR_TIME).
Maximum tool age for TOOL CALL?
CUR_TIME
Current age of the tool in minutes: The TNC automatically counts
the current tool life (CUR_TIME). A starting value can be entered
for used tools
Current tool age?
TYPE
Tool type: Press the SELECT TYPE (3rd soft-key row); the TNC
superimposes a window where you can select the type of tool
you want. You can assign tool types to specify the display filter
settings such that only the selected type is visible in the table
Tool type?
DOC
Comment on tool (up to 16 characters)
Tool comment?
PLC
Information on this tool that is to be sent to the PLC
PLC status?
PTYP
Tool type for evaluation in the pocket table
Tool type for pocket table?
TP_NO
Reference to the number of the touch probe in the touch-probe
table
Number of the touch probe
T_ANGLE
Point angle of the tool. Is used by the Centering cycle (Cycle 240)
in order to calculate the centering depth from the diameter entry
Point angle?
LAST_USE
Date and time that the tool was last inserted via TOOL CALL
Input range: Max. 16 characters, format specified internally: Date
= yyyy.mm.dd, time = hh.mm
LAST_USE
Abbr.
Inputs