Trans datum table, Trans datum reset, 10 .4 defining coor dinat e tr ansf or mations – HEIDENHAIN TNC 128 (77184x-01) User Manual
Page 270

270
Programming: Special functions
1
0
.4 Defining coor
dinat
e
tr
ansf
or
mations
TRANS DATUM TABLE
You can define a datum shift by selecting a datum number from a
datum table with the TRANS DATUM TABLE function. Proceed as follows
for the definition:
Show the soft-key row with special functions
Select the menu for defining various plain-language
functions
Select transformations
Select datum shifting with TRANS DATUM
Press the arrow key to move to TRANS AXIS
Select datum shifting with TRANS DATUM TABLE
If desired, enter the name of the datum table from
which you want to activate the datum number, and
confirm with the ENT key. If you do not want to define
a datum table, confirm with the NO ENT key
Enter the line number to be activated by the TNC, and
confirm with the ENT key
TRANS DATUM RESET
Use the TRANS DATUM RESET function to cancel a datum shift. How you
previously defined the datum is irrelevant. Proceed as follows for the
definition:
Show the soft-key row with special functions
Select the menu for defining various plain-language
functions
Select transformations
Select datum shifting with TRANS DATUM
Press the arrow key to move to TRANS AXIS
Select the TRANS DATUM RESET datum shift
Example: NC block
13 TRANS DATUM TABLE TABLINE25
If you did not define a datum table in the TRANS DATUM
TABLE
block, then the TNC uses the datum table already
selected in the NC program with SEL TABLE, or the datum
table with status M selected in one of the Program Run
modes.
Example: NC block
13 TRANS DATUM RESET