beautypg.com

Ii - 6 switching inputs and outputs – HEIDENHAIN PT 855 for Turning User Manual

Page 78

background image

II - 6

Switching Inputs and Outputs

80

Technical Information

POSITIP 855

II - 6
Switching Inputs and Outputs

Switching signals at the D-sub connection EXT allow you to

reset the actual value display of a coordinate axis to zero

control motor cutoff

start measured value output (see Chapter II - 5)

Interface X41 (EXT) complies with the recom-
mendations in VDE 0160, 5.88 for separation
from line power.

The outputs for the switching ranges are me-
tallically isolated from the device electronics by
means of optocouplers.

Danger to internal components!
Voltage from external circuitry must conform
to the recommendations in VDE 0100, Part 410
for low-voltage electrical separation.

Connect inductive loads such as relays only with
a quenching diode. Shield against electromag-
netic fields. Connect with a shielded cable with
the shield extended to the connector housing.

Pin layout of D-sub connection EXT (X41)

Pin

Assignment

10

0 V for switching range

23, 24, 25

24 V DC for switching range

11

POSITIP ready for operation

14

Display value outside of switching range 0

15

Display value outside of switching range 1

16

Display value outside of switching range 2

17

Display value outside of switching range 3

18

Display value outside of switching range 4

19

Display value outside of switching range 5

20

Display value outside of switching range 6

21

Display value outside of switching range 7

1

0 V (internal)

2

Reset axis 1 to zero

3

Reset axis 2 to zero

4

Reset axis 3 to zero

5

Reset axis 4 to zero

8

Pulse: output measured value

9

Contact: output measured value

6, 7, 12,

Do not use

13, 22

Outputs

Inputs

1

6

2

7

3

8

5

4

9

14

15

16

17

18

19

20

21

10

11

12

13

22

23

24

25

Fig. 45: The D-sub connection EXT