II - 3

Encoders and Measured Value Display

POSITIP 855

Technical Information

69

Definition of the coordinate axes: P 48.*

Do not display axis off:

P 48.* = 0

Display axis on:

P 48.* = 1

You can define separately for each axis whether the encoder sig-
nals are counted positive or negative in positive direction of
traverse.

Counting direction of the encoder signals: P 30.*

Positive counting direction:

P 30.* = 0

Negative counting direction:

P 30.* = 1

Monitoring of encoder:

cable and connectors

traversing speed

measuring signals

Encoder monitoring: P 45.*

Encoder monitoring off: P 45.* = 0
Encoder monitoring on: P 45.* = 1