beautypg.com

Ii - 1 installation and electrical connection, Items supplied installation, Installation and electrical connection – HEIDENHAIN PT 855 for Turning User Manual

Page 57: Ii - 1

background image

II - 1

Installation and Electrical Connection

POSITIP 855

Technical Information

59

Installation and Electrical Connection

Items supplied

POSITIP 855 Display Unit

Power connector

User's Manual

Installation

M4 screws are required for securing POSITIP to a support or a tilt-
ing base from HEIDENHAIN (Id.-Nr. 281 619 01). See Chapter II - 8
for the hole dimensions.

Electrical connection

Power connection

POSITIP requires AC voltage between 100 V and 240 V (48 Hz to
62 Hz). No voltage adjustment is required.

Wiring the power connector

See Fig. 30
Power leads: and
Ground:

Minimum cross-section of the power cable: 0.75 mm

2

II - 1

Fig. 30: Wiring the power connector

Danger of electrical shock!
Unplug the power cord before opening the hous-
ing. Connect a protective ground. This connection
must never be interrupted.

Danger to internal components!
Do not engage or disengage any connections while
the unit is under power. Use only original replace-
ment fuses.

L

N