beautypg.com

Example of character output at the data interface – HEIDENHAIN PT 855 for Turning User Manual

Page 77

background image

II - 5

Measured Value Output

POSITIP 855

Technical Information

79

3

1

4

5

6

Example of character output at the data interface

The numbers stand for

1

Coordinate axis

2

Blank space (separate value mode), S (sum mode) or
O (top slide)

3

Equality sign

4

+/– sign

5

Carriage return

6

Line feed

Example: Linear axis with sum display mode Z = + 5841.2907 mm

Z

S = + 5 8 4 1 .

2 9 0 7

R

2 to 7 places
Decimal point
1 to 6 places
Unit: blank space for mm, " for inches
Actual value display:

R for radius, D for diameter

Distance-to-go display:

r for radius, d for diameter

2