Setting the measured value display – HEIDENHAIN PT 855 for Turning User Manual
Page 70

II - 3
Encoders and Measured Value Display
72
Technical Information
POSITIP 855
Setting the measured value display
Designation of the coordinate axes: P49.
∗∗∗∗∗
Axis is coordinate axis A:
P 49.* = 65
Axis is coordinate axis B:
P 49.* = 66
Axis is coordinate axis C:
P 49.* = 67
Axis is coordinate axis X:
P 49.* = 85
Axis is coordinate axis Y:
P 49.* = 86
Axis is coordinate axis Z:
P 49.* = 87
Axis is coordinate axis U:
P 49.* = 88
Axis is coordinate axis V:
P 49.* = 89
Axis is coordinate axis W:
P 49.* = 90
Unit of measurement: P 1 (user parameter)
Display dimensions in millimeters (mm):
P 1 = 0
Display dimensions in inches (inch):
P 1 = 1
In the diameter display mode, the symbol for the diameter (Ø) appears next
to the display value, and the display value doubles.
Radius/diameter display: P 3.* (user parameter)
Display position values as radius:
P 3.* = 0
Display position values as diameter:
P 3.* = 1
In the separate value display mode, POSITIP displays the positions of the
saddle and top slide separately. In the sum display mode, the position val-
ues of the two axes are added together.
Separate value/sum display: P 5.* (user parameter)
Separate value display mode:
P 5.* = 0
Sum display mode:
P 5.* = 1