Setting the measured value display

Designation of the coordinate axes: P49.

∗∗∗∗∗

Axis is coordinate axis A:

P 49.* = 65

Axis is coordinate axis B:

P 49.* = 66

Axis is coordinate axis C:

P 49.* = 67

Axis is coordinate axis X:

P 49.* = 85

Axis is coordinate axis Y:

P 49.* = 86

Axis is coordinate axis Z:

P 49.* = 87

Axis is coordinate axis U:

P 49.* = 88

Axis is coordinate axis V:

P 49.* = 89

Axis is coordinate axis W:

P 49.* = 90

Unit of measurement: P 1 (user parameter)

Display dimensions in millimeters (mm):

P 1 = 0

Display dimensions in inches (inch):

P 1 = 1

In the diameter display mode, the symbol for the diameter (Ø) appears next
to the display value, and the display value doubles.

Radius/diameter display: P 3.* (user parameter)

Display position values as radius:

P 3.* = 0

Display position values as diameter:

P 3.* = 1

In the separate value display mode, POSITIP displays the positions of the
saddle and top slide separately. In the sum display mode, the position val-
ues of the two axes are added together.

Separate value/sum display: P 5.* (user parameter)

Separate value display mode:

P 5.* = 0

Sum display mode: