beautypg.com

HEIDENHAIN PT 855 for Turning User Manual

Page 69

background image

II - 3

Encoders and Measured Value Display

POSITIP 855

Technical Information

71

Setting the display step with linear encoders

Example settings for HEIDENHAIN linear encoders

Encoder

P31.

∗∗∗∗∗

P43.

∗∗∗∗∗

P32.

∗∗∗∗∗

Signal

Reference

Display step

Linear

period

marks

mm

inch

subdiv.

LIP 40x

2

0

0.001

0.000 05

2

0.000 5

0.000 02

4

0.000 2

0.000 01

10

0.000 1

0.000 005

20

0.000 05

0.000 002

40

0.000 02

0.000 001

100

LIP 101A

4

0

0.001

0.000 05

4

LIP 101R

0.000 5

0.000 02

8

0.000 2

0.000 01

20

0.000 1

0.000 005

40

0.000 05

0.000 002

80

LIF 101. LF 401

4

0

0.001

0.000 05

4

0.000 5

0.000 02

8

0.000 2

0.000 01

20

0.000 1

0.000 005

40

LID xxx

10

0

0.001

0.000 05

10

LID xxxC

2 000

0.000 5

0.000 02

20

LS 103. LS 103C

0

0.000 2

0.000 01

50

LS 405. LS 405C

or

0.000 1

0.000 005

100

ULS/10

1 000

LS 303. LS 303C

20

0

0.01

0.000 05

2

LS 603. LS 603C

or

0.005

0.000 02

4

1 000

LS 106. LS 106C

20

0

0.01

0.000 5

2

LS 406. LS 406C

or

0.005

0.000 2

4

LS 706. LS 706C

1 000

0.002

0.000 1

10

ULS/20

0.001

0.000 05

20

0.000 5

0.000 02

40

LIDA 190

40

0

0.002

0.000 1

20

LB 101

0.001

0.000 05

40

0.000 5

0.000 02

80

LIDA 2xx

100

0

0.01

0.000 5

10

LB 3xx

0.005

0.000 2

20

0.002

0.000 1

50

0.001

0.000 05

100

LIM 102

12 800

0

0.2

0.01

64

0.1

0.005

128