HEIDENHAIN PT 855 for Turning User Manual
Page 64
II - 2
Operating Parameters
66
Technical Information
POSITIP 855
Parameter
Page
Function and
Numerical
allowed entries
entry
*
P45.1 Encoder monitoring 1
69
Monitoring off
0
P45.1 ..........
P45.2 Encoder monitoring 2
Monitoring on
1
P45.2 ..........
P45.3 Encoder monitoring 3
P45.3 ..........
P45.4 Encoder monitoring 4
P45.4 ..........
P48.1 Axis definition 1
69
Do not display axis: off
0
P48.1 ..........
P48.2 Axis definition 2
Display axis: on
1
P48.2 ..........
P48.3 Axis definition 3
P48.3 ..........
P48.4 Axis definition 4
P48.4 ..........
P49.1 Axis designation 1
72
Axis is coordinate axis A
65
2)
P49.1 ..........
P49.3 Axis designation 3
Axis is coordinate axis B
66
2)
P49.3 ..........
Axis is coordinate axis C
67
2)
...................
Axis is coordinate axis U
85
2)
...................
Axis is coordinate axis V
86
2)
...................
Axis is coordinate axis W
87
2)
...................
Axis is coordinate axis X
88
2)
...................
Axis is coordinate axis Y
89
2)
...................
Axis is coordinate axis Z
90
2)
...................
P50
RS-232-C baud rate
76
Speed of data transfer
P50 .............
150 [Baud]
≤
P 50
≤
38 400 [baud]
9 600
P51
RS-232-C blank lines
78
Number of line feeds after output
P51 .............
of measured value [0 to 99]
1
P60.0 Switching output 0
81
Off
0
P60.0 ..........
P60.1 Switching output 2
Assigned to axis 1
1
P60.1 ..........
P60.2 Switching output 2
Assigned to axis 2
2
P60.2 ..........
P60.3 Switching output 3
Assigned to axis 3
3
P60.3 ..........
P60.4 Switching output 4
Assigned to axis 4
4
P60.4 ..........
P60.5 Switching output 5
P60.5 ..........
P60.6 Switching output 6
P60.6 ..........
P60.7 Switching output 7
P60.7 ..........
P61.0 Switching range 0
81
Enter the switching range
0.0
P61.0 ..........
P61.1 Switching range 2
symmetrically to zero in [mm]
P61.1 ..........
P61.2 Switching range 2
P61.2 ..........
P61.3 Switching range 3
P61.3 ..........
P61.4 Switching range 4
P61.4 ..........
P61.5 Switching range 5
P61.5 ..........
P61.6 Switching range 6
P61.6 ..........
P61.7 Switching range 7
P61.7 ..........
P69
Switching signal
78
Mode 1 (Signal delay 80 ms)
0
P69 .............
Mode 2 (Signal delay 5 ms)
1
P81.1 16/40µA switchover 1
68
Encoder signal 16 µA
0
P81.1 ..........
P81.2 16/40µA switchover 2
Encoder signal 40 µA
1
P81.2 ..........
P81.3 16/40µA switchover 3
P81.3 ..........
P81.4 16/40µA switchover 4
P81.4 ..........
1)
Standard factory settings are in
bold italics
2)
Factory setting for P 49.
∗
:
P49.1 =
88; P 49.3 = 90
List of operating parameters
✍
✍
✍
✍
✍