II - 5

Measured Value Output

78

Technical Information

POSITIP 855

Fig. 44: Time diagram for measured value out-

put with Ctrl B

Starting measured value output

C t r l B

C t r l B

t

1

t

3

t

2

t

D

R X D

T X D

Starting measured value output with Ctrl B

t

1

: Delay between Ctrl B command and internal latch

t

1

0.5 ms

t

2

: Delay between internal latch and measured value output

t

2

30 ms

t

3

: Time between end of data output and next latch with Ctrl B

t

3

0 ms

t

D

: Duration of measured value output

The duration of measured value output (t

D

) depends on

The selected baud rate (BR),

The number of axes (M)

The number of blank lines (L)

t

D

=

[s]

Operating parameters for measured value output

The following operating parameters will influence measured
value output — regardless of how you start it.

Number of blank lines after each measured value: P51

Number of blank lines after measured value: P51 = 0 to 99

You can also use the signal for measured value output to
influence position display.

Screen display during measured value output: P23

The display is not stopped during measured
value output (Off):

P23 = 0

The display is stopped during measured value output
and remains stopped as long as the switching input
“output measured value” is active (Concrnt):

P23 = 1

The display is stopped but is updated by every
measured value output (Frozen):

P23 = 2

BR

187

×

M + L

×

11