beautypg.com

Setting the display step with linear encoders – HEIDENHAIN PT 855 for Turning User Manual

Page 68

background image

II - 3

Encoders and Measured Value Display

70

Technical Information

POSITIP 855

Setting the display step with linear encoders

With linear encoders, the display step depends on the

signal period of the encoder (P31.

) and the

linear subdivision (P32.

).

Both parameters are entered separately for each axis. The linear
subdivision can range from 0.1 to 128 depending on the signal
period of your encoder.

For linear measurement using nut/ballscrew arrangements and
rotary encoders, calculate the signal period as follows:

Signal period [µm] =

Drivescrew pitch [mm] x 1000

Line count

Display step, signal period and linear subdivision for linear encoders

Signal period [µm]

2

4

10

20

40

100

200 12 800

Display step
[mm]

[inch]

Linear subdivision

0.000 02

0.000 001

100

0.000 05

0.000 002

40

80

0.000 1

0.000 005

20

40

100

0.000 2

0.000 01

10

20

50

100

0.000 5

0.000 02

4

8

20

40

80

0.001

0.000 05

2

4

10

20

40

100

0.002

0.000 1

1

2

5

10

20

50

100

0.005

0.000 2

0.4

0.8

2

4

8

20

40

0.01

0.000 5

0.2

0.4

1

2

4

10

20

0.02

0.001

0.5

1

2

5

10

0.05

0.002

0.2

0.4

0.8

2

4

0.1

0.005

0.1

0.2

0.4

1

2

128

0.2

0.01

64