Setting the display step with linear encoders – HEIDENHAIN PT 855 for Turning User Manual
Page 68

II - 3
Encoders and Measured Value Display
70
Technical Information
POSITIP 855
Setting the display step with linear encoders
With linear encoders, the display step depends on the
•
signal period of the encoder (P31.
∗
) and the
•
linear subdivision (P32.
∗
).
Both parameters are entered separately for each axis. The linear
subdivision can range from 0.1 to 128 depending on the signal
period of your encoder.
For linear measurement using nut/ballscrew arrangements and
rotary encoders, calculate the signal period as follows:
Signal period [µm] =
Drivescrew pitch [mm] x 1000
Line count
Display step, signal period and linear subdivision for linear encoders
Signal period [µm]
2
4
10
20
40
100
200 12 800
Display step
[mm]
[inch]
Linear subdivision
0.000 02
0.000 001
100
–
–
–
–
–
–
–
0.000 05
0.000 002
40
80
–
–
–
–
–
–
0.000 1
0.000 005
20
40
100
–
–
–
–
–
0.000 2
0.000 01
10
20
50
100
–
–
–
–
0.000 5
0.000 02
4
8
20
40
80
–
–
–
0.001
0.000 05
2
4
10
20
40
100
–
–
0.002
0.000 1
1
2
5
10
20
50
100
–
0.005
0.000 2
0.4
0.8
2
4
8
20
40
–
0.01
0.000 5
0.2
0.4
1
2
4
10
20
–
0.02
0.001
–
–
0.5
1
2
5
10
–
0.05
0.002
–
–
0.2
0.4
0.8
2
4
–
0.1
0.005
–
–
0.1
0.2
0.4
1
2
128
0.2
0.01
–
–
–
–
–
–
–
64