Operating Parameters

64

Technical Information

POSITIP 855

User parameters

The machine manufacturer has defined certain operating param-
eters as user parameters. You can change the settings of user
parameters without having to enter a code number (see Operating
Instructions section, Chapter I - 6).

Position of user parameters in the menu

In operating parameters P100 to P120, the machine manufacturer
defines how the user parameters are arranged in the soft key
displays.

Field 15 is reserved for the soft key

Code Number

If a parameter is assigned to field number 0, it will not appear in
the user parameter menu.

Operating

User parameter

Standard

parameter

designation

*

field

P 100

mm / inch (P 1)

4

........

P 101.1

Radius / diameter 1 (P 3.1)

1

P 101.3

Radius / diameter 3 (P 3.3)

0

........

P 102.1

Separate / sum 1 (P 5.1)

0

........

P 102.3

Separate / sum 3 (P 5.3)

2

........

P 104

Scaling factor On / Off (P 11)

8

........

P 105.1

Scaling factor 1 (P 12.1)

6

........

P 105.3

Scaling factor 3 (P 12.3)

7

........

P 106

Oversize On / Off (P 14)

13

........

P 107.1

Oversize 1 (P 15.1)

11

........

P 107.3

Oversize 3 (P 15.3)

12

........

P 112

RS-232 baud rate (P 50)

0

........

P 113

RS-232 blank lines (P 51)

0

........

P 120

Tool table

5

........

*

The corresponding operating parameters are indicated in
parentheses.

11

6

1

12

7

2

13

8

3

14

9

4

15

10

5

Fig. 37: Field numbering for user parameters