beautypg.com

HEIDENHAIN PT 855 for Turning User Manual

Page 46

background image

I - 3

Programming POSITIP

POSITIP 855

Operating Instructions

47

Press

Start Output

to transfer the program to the external device.

The message

Reading out program:

appears.

C A U T I O N

A program on the external device with the same number
as that being read out will be overwritten. No confirma-
tion to overwrite will be requested.

To read all programs out of POSITIP's memory:

➤ Press Output All PGM

For program output, POSITIP automatically displays all programs
stored in its memory.

Example: Reading a program out of POSITIP

Operating mode:

PROGRAMMING AND EDITING

Select

Extern

.

Go to

EXTERNAL OUTPUT

.

/

Select the external device.
For diskette unit or PC with HEIDENHAIN data transfer software TNC.EXE
use FE setting; for PC without TNC.EXE (or printer) use EXT setting.

P r o g r a m n u m b e r ?

1

0

Enter the program number, for example 10.

Transferring programs over the data interface