DFE-Gold Module Shutdown Procedure
4-8 Troubleshooting
When a controlled shutdown is initiated from the OFFLINE/RESET
switch
, you have 60
seconds from the time the CPU starts alternately flashing amber/off until the device
automatically restarts.
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch
To reset a DFE‐Gold module without it performing an orderly shutdown routine,
press and hold the OFFLINE/RESET switch for approximately 6 seconds.
Removing any DFE‐Gold module from the chassis before it has been shut down is not
recommended. The only safe time to remove a module from the chassis is after the
completion of a shutdown and the management LED is alternately flashing amber/off.
Note: The only safe time to remove a DFE-Gold module from the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.
Caution: This method of shutting down a DFE module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted,
resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos DFE.
Recurra a él sólo como último recurso, puesto que interrumpe todos los procesos del
módulo en funcionamiento, lo que podría resultar pérdidas de frames.