DFE-Gold Module Shutdown Procedure

4-8 Troubleshooting

When a controlled shutdown is initiated from the OFFLINE/RESET

switch

, you have 60 

seconds from the time the CPU starts alternately flashing amber/off until the device 
automatically restarts.

Last Resort Shutdown Procedure Using OFFLINE/RESET Switch

To reset a DFE‐Gold module without it performing an orderly shutdown routine, 

press and hold the OFFLINE/RESET switch for approximately 6 seconds. 

Removing any DFE‐Gold module from the chassis before it has been shut down is not 
recommended. The only safe time to remove a module from the chassis is after the 
completion of a shutdown and the management LED is alternately flashing amber/off.

Note: The only safe time to remove a DFE-Gold module from the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.

Caution: This method of shutting down a DFE module is not recommended except as a
last resort, because all processes currently running on the module will be interrupted,
resulting in loss of frames.