Table 4-1 lanview leds, Lanview leds -3 – Enterasys Networks Enterasys Matrix 6H303-48 User Manual
Page 67
Using LANVIEW
Matrix DFE-Gold Series Installation Guide 4-3
describes the LED indications and provides recommended actions as
appropriate.
The terms flashing, blinking, and solid used in
indicate the following:
• Flashing indicates an LED is flashing randomly.
• Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50%
off).
• Solid indicates a steady LED light. No pulsing.
• Alternating indicates an LED is flashing in a steady rate other than 50% on, 50% off.
Table 4-1 LANVIEW LEDs
LED
Color
State
Recommended Action
MGMT
None
Off. This module is NOT the
Management Module.
None.
Green
Solid. This module is the
designated Management
Module.
None.
Amber
Flashing. This is a
temporary indication that the
module is saving data.
None.
CPU
None
Power off.
Ensure chassis has adequate power.
Amber
Blinking. Module in process
of booting.
None.
Solid. Testing.
If the LED remains amber for several
minutes, contact Enterasys Networks
for technical support.
Green
Blinking. Image starts
running.
None.
Solid. Functional.
None.
Red
Solid. Processor in reset.
None.
Green
and
Amber
Blinking. Indicates that the
module is in the process of
shutting down.
None. This state is activated when the
OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.
While in this state, do not remove any
DFE-Gold module from the chassis.