Scale factor screen, 2 s o ft wa re s e tu p – HEIDENHAIN ND 100 User Manual User Manual
Page 94

94
2 Installation and Specifications
2
.2
S
o
ft
wa
re
s
e
tu
p
Measurement scaling for parts that expand or
shrink
Scale factors scale measurement results using a multiplier and are
useful when measuring parts that will expand or shrink after
inspections have been performed.
Scale Factor screen
The Scale Factor screen contains configuration fields for:
Enabling scale factor
Specifying a scale factor multiplier value
Providing the user access to scale factor editing
To configure scale factor settings:
Press MENU>Setup to display the Setup menu and then highlight the
Scale Factor menu item.
Highlight the Multiplier data field and enter the scale factor
multiplier.
Highlight the User Access choice field and press the No soft key to
restrict access to those who can provide the supervisor password,
or the Yes soft key to provide unrestricted access.
Highlight the Active choice field and press the No soft key to disable
the scale factor or the Yes soft key to enable it.
Press the FINISH key to return to the Setup menu.
Notice
The setup process for all axes is identical and uses the
Encoders and Misc setup screens.
Notice
Password restricted access to setup parameters is
explained earlier on page 68.
Enter the scale factor multiplier
Select No to restrict access or Yes to
allow user access to scale factor editing
Select No to disable or Yes to enable
scale factor