beautypg.com

Verify controls – Grass Valley JSC-2300 SHOT User Manual

Page 41

background image

Ignite JSC-2300 SHOT Director Robotics/Camera Controller Instruction Manual

41

Setup SHOT Director Controller

5.

Using the joystick, navigate to and then click

OK

to complete the

calibration. The

CAMERA CONTROL

Home dialog box (

Figure 13

) appears.

6.

Check default operation between the SHOT Director controller and the
camera.

a.

Press the

CAMERA

button (

Figure 10

). The

CAMERA

Select dialog box

(

Figure 31

) appears.

Figure 31. Camera Select Dialog Box

b.

Using the joystick, select the

CAMERA

box, type 16, and then press the

enter

button (

Figure 10

). The

CAMERA CONTROL

Home dialog box

(

Figure 13

) now indicates

Camera 16

in the top right corner and the

Pan

,

Tilt

,

Zoom

,

Focus

, and

Iris

values change as the joystick, zoom

control, focus knob, and iris knob are rotated.

Verify Controls

Note

Do not attempt to control a robotic camera until proper operation of SHOT
Director controls is verified.

1.

Press the

Setup

button (

Figure 8

). The

MAIN SETUP MENU

dialog box

(

Figure 15

) appears.

2.

Select

DIAG

(

Figure 15

). The

DIAGNOSTICS

dialog box (

Figure 26

) appears

and the

AUTO IRIS

indicator blinks continuously.

3.

Center the joystick, then verify that the first three sets of numbers in the
second row of

RAW POT VALUES

are greater than -30 and less than 30. If

the values are outside this range, perform a manual joystick calibration
(refer to

Calibrate Joystick on page 39

).

4.

Move the

ZOOM

and

PAN/TILT SPEED CONTROL

sliders from one end of

travel to the other end of travel. Verify that the fourth and fifth set of

RAW POT VALUES

read 0 (±2) to 50 (±2) as the sliders are moved. If the

values are outside this range, perform a manual joystick calibration
(refer to

Calibrate Joystick on page 39

).

5.

Rotate the

FOCUS CONTROL

knob and verify that it operates smoothly for

several rotations in each direction. Verify that the

FOCUS

numerical

display on the

DIAGNOSTICS

dialog box changes with the rotation of the

knob.

8

4

9

3_

sc00_r0