Ignite JSC-2300 SHOT Director Robotics/Camera Controller Instruction Manual

Section 2 — Functional Description

Diagnostics Dialog Box

The

DIAGNOSTICS

dialog box (

Figure 26

) is used diagnose/troubleshoot the

SHOT Director controls (joystick, knobs, and buttons). To access it, press
the

Setup

button, then select

DIAG.

It enables a user to:

Figure 26. Diagnostics Dialog Box

RAW POT VALUES:

Display raw input values to the embedded micro-con-
troller in the joystick. The raw pot values from left to
right are zoom, tilt, pan, zoom speed slider, pan/tilt
speed slider.

1st row: Absolute analog to digital (A/D) conversion
values.

2nd row: Zero values offset from center. If the first 3
values are outside the range of greater than -30 and less
than 30 when the joystick is centered, the joystick
requires calibration (refer to

Calibrate Joystick on page 39

).

Grid (lower left):

Test the on/off operation of each key on the controller.

FOCUS:

Test

FOCUS CONTROL

knob raw pot values

IRIS:

Test MANUAL IRIS knob raw pot values

OK:

Close the

DIAGNOSTICS

dialog box