the Diagnostic mode, a quick push of the Selector cycles through the various diagnostic
sub-modes described above.

The following table describes the expected readouts in each of the above Base Station
display modes. By following the sequence, you can understand what the various readouts
and four-character abbreviations mean for the system.

Display Mode

Readout

Base Station Digital Display Activity Explanation

(assumes after initial power up - see Page xx for a description of the Power Up sequence)

BASE RX (Base Station Receive Signal Strength)

BASE RX

-9

Indicates that the Base Station signal strength is -9 dBm

BASE RX

OPT

Indicates that the Display is showing Optical link signal
strength

BASE RX

-9

Repeat of the Base Station signal strength

BASE RX

OPT

Repeat that the display is showing Optical link signal
strength

This display cycle repeats itself and depending on timing
may start with either OPT of the strength measurement

CAM RX (Camera Unit Receive Signal Strength)

CAM RX

COPT

Sequence starts with COPT to indicate camera optical
signal strength

CAM RX

-9

Indicates that the signal strength from the Camera Unit is
-13 dBm

CAM RX

OPT

Indicates that the Display is showing Optical link signal
strength
Note: the only way to distinguish between BASE RX and
CAM RX is to check the Display Mode LED indicator

CAM RX

-9

Repeat of the Camera Unit signal strength

CAM RX

OPT

Repeat that the display is showing Optical link signal
strength

This display cycle repeats itself and depending on timing
may start with either OPT of the strength measurement -
COPT does not reappear in the repeating cycle

DIAGNOSTIC MODE Temperature (TEMP)

DIAG

When first entering the Diagnostic mode the DIAG display
mode indicator LED will blink - the first sub-mode is TEMP
(Temperature). The Digital Display Characters will glow
Green when the temperature is normal and Red when
outside of normal range.

DIAG/TEMP

TEMP

Indicates the display is in the TEMP sub-mode

DIAG/TEMP

PS

The Power Supply (PS) temperature will be displayed

DIAG/TEMP

TEMP

Repeats that the display is in the TEMP sub-mode

DIAG/TEMP

37C

Temperature display in Centigrade for Power Supply
circuit board

DIAG/TEMP

BASE

The Base Station main circuit board temperature will be
displayed

DIAG/TEMP

TEMP

Repeats that the display is in the TEMP sub-mode