Grass Valley 3050 CopperHead User Manual
Page 30

24
Detailed Description
CopperHead 3050 Base Station Front Panel
• Green when both the Base Station and Camera Unit optical power are within a
normal range
• Red when both the Base Station and camera optical power are not within a
normal range
• Orange when either the Base Station or camera optical power are not within a
normal range
• ALARM - indicates that some error condition exists in either the Base Station or the
Camera Unit:
• Red if there is a Base Station error. Refer to the Base Station DIAG for details on
The CopperHead 3050 Base Station Digital Display
• Orange if there is a Camera Unit error. Refer to CAM DIAG for details for the
error (see
The CopperHead 3050 Camera Unit Digital Display
• 13 - Hybrid Power Indicators
The Hybrid Power indicators are only applicable to units with the internal power supply
(for configurations using the MPS power supply - see
MPS External Power Wafer Power
• CAMERA POWER - indicates that high voltage is applied to the Hybrid Cable
connector (OpticalCONN or SMPTE 304M), which powers the Power Wafer at the
Camera Unit.
• Green when high voltage is being supplied to the Hybrid cable connector
• Off when there is no high voltage applied to the Hybrid cable connector
• CABLE OPEN - indicates that there is no hyrbid cable connected to a Camera Unit
equipped with a Power Wafer.
• Green when the hybrid cable is properly connected from the Base Station to
the Camera Unit equipped with Power Wafer
• Red when there no cable connected to the camera or the cable is connected
but open
High voltage will not be applied to the camera until the open condition is
corrected.
• CABLE SHORT - indicates that the hybrid cable connected is shorted.
• 14 - Power Switch & Power Indicator
Toggle switch to enable or disable Base Station power.
LED turns Green when ON/OFF switch is changed to the ON position. With a hybrid
power system (power supplied by the Base Station), this switch will control power to
the Camera and the Camera Unit
For the hybrid system to be properly powered, the AC Mains switch on the rear of Base
Station must be in the ON position.
Note:
Hybrid Power Indicators are present only on a hybrid power unit.