Environmental Criteria
The following table lists the environmental criteria for Aurora Playout.
Category
Standard
Safety
Designed/tested for compliance with:
ANSI/UL60950-2000 - Safety of Information Technology Equipment
IEC 60950 - Safety of Information Technology Equipment (3rd edition, 1999)
CAN/CSA C22.2, No. 60950-00 - Safety of Information Technology Equipment
EN60950:2000 - Safety of Information Technology Equipment (3rd edition)
Characteristics
Description
Operating Temperature
Requirement:
10° to 40°C
Storage Temperature
Requirement:
-40° to 65°C
Operating Altitude
Requirement: To
10,000
feet
Supplemental Data:
IEC 60950 compliant to
2000 meters
Storage Altitude
Requirement: To
40,000
feet
Mechanical Shock
Supplemental Data:
Class 5 (30G) Grass Valley
001131500
Random Vibration
Requirement:
Operational: Class 6 Grass
Valley 001131500
Requirement: Non-Operational:
Class
5
Grass Valley 001131500
Transportation
Requirement: Grass
Valley
001131500
Equipment Type
Supplemental Data: Information
Technology
Equipment Class
Supplemental Data: Class
1
Installation Category
Requirement:
Category II Local level
mains, appliances,
portable equipment, etc.
Pollution Degree
Requirement:
Level 2 operating
environment, indoor use only.
Relative Humidity
Requirement:
Operating 80% from +30° to
+40°C
Non-Operating 90% from
+30° to +60°C
Do not operate with visible
moisture on the circuit boards.