Environmental Criteria

The following table lists the environmental criteria for Aurora Playout.

Category

Standard

Safety

Designed/tested for compliance with:
ANSI/UL60950-2000 - Safety of Information Technology Equipment
IEC 60950 - Safety of Information Technology Equipment (3rd edition, 1999)
CAN/CSA C22.2, No. 60950-00 - Safety of Information Technology Equipment
EN60950:2000 - Safety of Information Technology Equipment (3rd edition)

Characteristics

Description

Operating Temperature

Requirement:

10° to 40°C

Storage Temperature

Requirement:

-40° to 65°C

Operating Altitude

Requirement: To

10,000

feet

Supplemental Data:

IEC 60950 compliant to

2000 meters

Storage Altitude

Requirement: To

40,000

feet

Mechanical Shock

Supplemental Data:

Class 5 (30G) Grass Valley

001131500

Random Vibration

Requirement:

Operational: Class 6 Grass

Valley 001131500
Requirement: Non-Operational:

Class

5

Grass Valley 001131500

Transportation

Requirement: Grass

Valley

001131500

Equipment Type

Supplemental Data: Information

Technology

Equipment Class

Supplemental Data: Class

1

Installation Category

Requirement:

Category II Local level

mains, appliances,

portable equipment, etc.

Pollution Degree

Requirement:

Level 2 operating

environment, indoor use only.

Relative Humidity

Requirement:

Operating 80% from +30° to

+40°C

Non-Operating 90% from

+30° to +60°C

Do not operate with visible

moisture on the circuit boards.