[SwitchB] vsan 1
[SwitchB-vsan1] zone default-zone permit
[SwitchB-vsan1] quit
Verifying the configuration
# Verify the configuration on Switch A.
[SwitchA-vsan1] display fc domain vsan 1
Domain Information of VSAN 1:
Running time information:
State: Stable
Switch WWN: 48:33:43:2d:46:43:1A:1A
Fabric name: 11:11:11:11:11:11:11:11
Priority: 128
Domain ID: 1
Configuration information:
Domain configure: Disabled
Domain auto-reconfigure: Disabled
Fabric name: 11:11:11:11:11:11:11:11
Priority: 128
Domain ID: 1 (static)
Principal switch running time information:
Priority: 128
No interfaces available.
The output shows that the domain configuration is complete and that the runtime domain ID of Switch A
is 1.