Verifying the configuration – H3C Technologies H3C S10500 Series Switches User Manual
Page 140
![background image](https://www.manualsdir.com/files/812733/content/doc140.png)
129
[SwitchA] fcping fcid fffc03 vsan 1
FCPING fcid 0xfffc03: 128 data bytes, press CTRL_C to break.
Request time out
Request time out
Request time out
Request time out
Request time out
--- 0xfffc03 fcping statistics ---
5 packet(s) transmitted
0 packet(s) received
100.00% packet loss
The output shows that Switch A cannot reach Switch C.
5.
Use the fctracert command to identify the faulty node.
[SwitchA] fctracert fcid fffc03 vsan 1
Route present for: 0xfffc03, press CTRL_C to break
20:00:00:0b:46:00:02:82(0xfffc01)
20:00:00:05:30:00:18:db(0xfffc02)
Fctracert uncompleted: no route to destination port.
The output shows that:
{
Switch A can reach Switch B.
{
Switch B cannot reach Switch C.
Verifying the configuration
# Use the display fc routing-table command on Switch B to verify that there is not a route to Switch C.
(Details not shown.)