Verifying the configuration – H3C Technologies H3C S10500 Series Switches User Manual
Page 112
![background image](https://www.manualsdir.com/files/812733/content/doc112.png)
101
[SwitchB] quit
# Configure the switch to operate in FCF mode.
[SwitchB] fcoe-mode fcf
# Create VSAN 1.
[SwitchB] vsan 1
[SwitchB-vsan1] quit
# Create interface VFC 3.
[SwitchB] interface vfc 3
# Configure the mode of VFC 3 as F.
[SwitchB-Vfc3] fc mode f
# Bind VFC 3 to interface Ten-GigabitEthernet 1/0/3.
[SwitchB-Vfc3] bind interface ten-gigabitethernet 1/0/3
# Assign VFC 3 to VSAN 1 as a trunk port.
[SwitchB-Vfc3] port trunk vsan 1
[SwitchB-Vfc3] quit
# Configure Ten-GigabitEthernet 1/0/3 as a trunk port, and assign the port to VLAN 10.
[SwitchB] interface ten-gigabitethernet 1/0/3
[SwitchB-Ten-GigabitEthernet1/0/3] port link-type trunk
[SwitchB-Ten-GigabitEthernet1/0/3] port trunk permit vlan 10
[SwitchB-Ten-GigabitEthernet1/0/3] quit
# Enable FCoE for VLAN 10 and map VLAN 10 to VSAN 1.
[SwitchB] vlan 10
[SwitchB-vlan10] fcoe enable vsan 1
[SwitchB-vlan10] quit
Verifying the configuration
# Display the nodes on downlink interfaces and their mapped uplink interfaces.
[SwitchA] display npv login
Server External
Interface VSAN FCID Node WWN Port WWN Interface
Vfc1 1 0x010001 21:00:00:00:c8:00:e4:30 20:00:00:00:c8:60:e4:9a Vfc3
Vfc2 1 0x010002 21:00:00:00:c9:00:e4:30 20:00:00:00:c9:60:e4:9a Vfc3
# Display information about uplink and downlink interfaces on Switch A.
[SwitchA] display npv status
External Interfaces:
Interface: Vfc3 VSAN tagging mode: Tagging
VSAN State FCID
1 Up 0x010000
Number of External Interfaces: 1
Server Interfaces:
Interface : Vfc1 VSAN tagging mode: Tagging