H3C Technologies H3C S10500 Series Switches User Manual
Page 168
![background image](https://www.manualsdir.com/files/812733/content/doc168.png)
157
[SwitchC-Ten-GigabitEthernet1/0/5] qos trust dot1p
[SwitchC-Ten-GigabitEthernet1/0/5] quit
# Configure interfaces Ten-GigabitEthernet 1/0/6 through Ten-GigabitEthernet 1/0/8 in the
same way Ten-GigabitEthernet 1/0/5 is configured.
[SwitchC] interface ten-gigabitethernet 1/0/6
[SwitchC-Ten-GigabitEthernet1/0/6] priority-flow-control enable
[SwitchC-Ten-GigabitEthernet1/0/6] priority-flow-control no-drop dot1p 3
[SwitchC-Ten-GigabitEthernet1/0/6] qos trust dot1p
[SwitchC-Ten-GigabitEthernet1/0/6] quit
[SwitchC] interface ten-gigabitethernet 1/0/7
[SwitchC-Ten-GigabitEthernet1/0/7] priority-flow-control enable
[SwitchC-Ten-GigabitEthernet1/0/7] priority-flow-control no-drop dot1p 3
[SwitchC-Ten-GigabitEthernet1/0/7] qos trust dot1p
[SwitchC-Ten-GigabitEthernet1/0/7] quit
[SwitchC] interface ten-gigabitethernet 1/0/8
[SwitchC-Ten-GigabitEthernet1/0/8] priority-flow-control enable
[SwitchC-Ten-GigabitEthernet1/0/8] priority-flow-control no-drop dot1p 3
[SwitchC-Ten-GigabitEthernet1/0/8] qos trust dot1p
[SwitchC-Ten-GigabitEthernet1/0/8] quit
5.
Configure FCoE:
# Configure the switch to operate in FCF mode.
[SwitchC] fcoe-mode fcf
# Enable the fabric configuration feature for VSAN 100. By default, the fabric configuration
feature is enabled.
[SwitchC] vsan 100
[SwitchC-vsan100] domain configure enable
# Set the switch priority to 1, so the switch can be selected as the principal switch.
[SwitchC-vsan100] priority 1
# Set the domain ID to 1.
[SwitchC-vsan100] domain-id 1 preferred
Non-disruptive reconfiguration or isolating the switch may be performed. Continue?
[Y/N]:y
# Enable FSPF.
[SwitchC-vsan100] fspf enable
[SwitchC-vsan100] quit
# Create interface VFC 1.
[SwitchC] interface vfc 1
# Configure the mode of VFC 1 as F.
[SwitchC-Vfc1] fc mode f
# Bind VFC 1 to interface Ten-GigabitEthernet 1/0/1.
[SwitchC-Vfc1] bind interface ten-gigabitethernet 1/0/1
# Assign VFC 1 to VSAN 100 as a trunk port.
[SwitchC-Vfc1] port trunk vsan 100
[SwitchC-Vfc1] quit
# Create interface VFC 10.
[SwitchC] interface vfc 10